ESR Error messages
Error messages can be found on the printout in column 10. Error codes are also included in the data string of the various protocols, for explanation of reading data: Protocol data and Limit error settings. ESR Error code messages: ESR "ERROR" and "WARNING" code messages. This code appears in the "sample data record" at column 10. The following codes are defined:
Limit error settings: When an option (at Limit error settings) is set to YES and this limit error occurs, results will be printed/send to the LIMS. Together with the sedimentation time and dilution rate (which are still printed at the usual position), the operator/analyst can see what caused the error and may or may not use the ESR values which are preserved in the error message. When an option is set to NO and this limit error occurs, the fields for 30 min ESR, 60 min ESR and the temperature corrected ESR are filled with spaces and thus results are not printed/send to the LIMS. The error message in the error field (column 10) indicates that at least one of the limits (ESR time, dilution rate, column height, bubbles on top, hazy aspects and temperature) has been exceeded. Description of the error message L_err(hhh/www/ttt/ccc) :
Example of a limit error message:
Note: If limit error filters in the LIMS are not corresponding with the limit error settings on the instrument it is possible that not all expected results are send to the LIMS. Hazy aspect codes: The following 4 codes are defined:
Results with hazy aspect can be suppressed in the menu Limit error settings (Limit error settings, Limit error settings). More information about Limit error settings (Limit error settings, Limit error settings)
Error messages can be found on the printout at the bottom line in reversed colours. If errors are found during the measurement, the Instrument will give an audible alarm. ESR Error code messages Error: No ESR result is given
Result at limit errors: When this option is set to YES and this limit error occurs, results will be printed/send to the LIMS. Together with the sedimentation time and dilution rate (which are still printed at the usual position), the operator/analyst can see what caused the error and may or may not use the ESR values which are preserved in the error message. When this option is set to NO and this limit error occurs, the fields for 30 min ESR, 60 min ESR and the temperature corrected ESR are filled with spaces and thus results are not printed/send to the LIMS. The error message in the error field (line D) indicates that at least one of the limits (ESR time, dilution rate or column height) has been exceeded. Description of the error message L_err(hhh/www/ttt/ccc) :
Example of a limit error message:
Note: If limit error filters in the LIMS are not corresponding with the limit error settings on the instrument it is possible that not all expected results are send to the LIMS. Hazy code messages: This code appears in the "sample data record" at line A. The following 4 codes are defined:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||